5C-125 siren with strobe

High Power Siren With Battery Back-up and Flashlight
Order Hotline
No such product
Inquiry
Description
Packing

Manual Installation 

 

Induction:
This is a new generation of professional high power acoustic siren with battery back-up and flashlight, which includes all performance and reliability for security alarm system.


Features:
◆Outdoor battery back-up siren with flashlight.
◆Double housing: External - 3mm plastic PC with UV, internal-0.8mm metal.
◆Continuous frequency modulated sound.
◆Tamper protection in 3 ways: screw or cover opening or tearing housing from the wall.
◆Positive and negative alarm trigger input.
◆Trigger input to active only the flashlight.
◆Siren period can set as follow trigger or 3 min cutoff
◆Select from the lamp or LED
◆Alarm by main power failure
◆Protecting against totally battery discharge
◆Plug terminal for easy installation.
◆Environmental immunity


Functional Description Alarm Trigger
The alarm can be triggered by applying high or low voltage to the “TR+” or “TR-”inputs terminals respectively. The sound and flashlight triggered together. 

Alarm siren duration depended on the trigger selector state when the LED or lamp is follow light.
◆F.T - Follow Trigger.
◆TMR-siren cutoff after 3 minutes, this state is recommended in order to avoid violation of any local regulations.


Flash Trigger:
The flashlight can be triggered by applying “low” level to “FL-” terminal. Flashlight duration is not limited and the time of flashlight is set by control panel-as long as trigger available the flashlight will be active.


Tamper:
The tamper is normally closed while the housing is closed with the screw, so in this state the tamper terminals are shorted (0 ohm).The tamper will open while opening the screw the tamper socket to the wall properly.


Power Failure:
On power failure the siren and flashlight are triggering, until power supply is restored or time out (5 minutes) expires.

 

Battery Protection:
The siren is supplied with protection against totally battery discharge by cutting off the siren, when voltage level falls down to less than 8VDC.

 

Installation instructions
1.Choose the mounting location for the siren - the wall must be even and free of hole and excessive protrusions.
2.Mark and drill 5 holes with help of attach drill pattern plate (4 holes for the housing based and 1 for the tamper).

Note: Take a consideration about the wires inputs in the housing base.

3.Open the siren housing(1 screw on the front), and remove the metal cover (2 screws)
4.Unplug the terminals on the siren driver
5.Mount the siren housing on the wall.
6.connect the wires to the terminals.

Important: Cut off the power before you make the connection

7.Plug the terminals to your drive board.
8.Power on the system and check that its function properly
9.Connect the back-up battery

Important: keep attention the polarity of the battery; a reverse polarity can cause damage of the driver circuit.

10.Mount the metal cover by 2 screws
11.Close the housing by 1 screw.         

 

Terminal Block Connection
Terminal 1- Marked “FL-”trigger for the flashlight connect it to output in the alarm system, Active while the input is low.
Terminal 2- Marked “TR+” trigger for the siren and the flashlight, Active while the input is high.
Terminal 3- Marked “TR-” trigger for the siren and flashlight, active while the input is low.
Terminal 4- Marked the “GND” connect to
the ground of the control unit.
Terminal 5- Marked “+14V” connect to a
positive voltage output of the 12-14VDC source (usually from the alarm control unit).
Terminal 6&7- Marked “TAMPER” if a tamper function is required connect these terminals to a 24-hour normally closed the protective zone in the control unit, if the front cover of the siren is opened or siren box is tearing from the wall, an immediate alarm signal will be sent to the control unit. 

 

Specification                                                       

SPL

128db

Fundamental Frequency

1850Hz

Siren Tone

Yelp

Frequency Range

1300-2400Hz

Flash light

Lamp 12VDC/5W

Power supply Voltage

12~14 VDC

Charge Current Limit

250mA

Current Consumption(Speaker and strobe)

Standby:8mA

Alarm 1600mA@13.8VDC

Maximum Power

50W(peak)

Trigger Level

Trigger Low=Max.1VDC

Trigger High=Min.9VDC

Siren Alarm Period (when LED follow light)

FT-Follow trigger

TMR-3 min

LED or lamp state setting

FL-Follow light

LMP-Lamp flash light

Input Impedance(Alarm/Flash/Trigger)

1K ohm

Tamper Switch

N.C 28VDC Maximum current 0.1A-open when cover is removed

Backup Battery

Rechargeable Lead Acid Battery 12VDC up to 1.3Ah

Low Battery Level

8VDC+/-0.3VDC

Material

External Box: ABS(3mm Thickness)

Internal cover: metal(0.8mm thickness)

Dimensions of Unit

L=270mm*W=193mm*H=100mm

Weight(without battery)

1.85Kg

Operating Temperature Range

-30 to +60℃

Case Protection Level

Water splash resistant

Plastic PC with UV Protection

Conformal coated circuit board

 

 

       

 

 